HOME
ABOUT US
DESTINATIONS
Aggressor Fleet
Bikini Atoll
Bikini Costs
Galapagos Islands
Grotta Giusti
Gozo
Lipari
Maratea
Palau
Red Sea
Scapa Flow
Truk Lagoon
COLTRI
PRODUCTS
TERMS & CONDITIONS
CONTACT US
LINKS |
Coltri Compressors
(portable)
Coltri Compressors (static)
Coltri Compressors (Nitrox)
Coltri Lamps
In our opinion, the best in the world. Contact us for prices
|
MCH 6/SH Explorer Nitrox - 3.5 cfm Honda Petrol
- Charging rate : 100l/min - 6m3/h - 3.5 cfm
- Filling time cylinder : 10 L - 0-200 Bar 20 min
- Working pressure : 225 Bar 3200 psi
- Driven by : Honda petrol engine
- Power : 4 Kw - 5,5 HP @ 3600 giri/min - rpm
- Fuel consumption : 0,987 L/h / 1,04 quarts/hour
- Measurements : H 55.8cm x L 129.5cm x W 40.6cm
- Weight : 61 KG
- Noise Level : 87 dB - ISO 3746
- Number of stages : 4
- Number of cylinders : 4
- Fuel : Unleaded petrol
- Fuel tank capacity : 2,7 L / 2,85 quarts
- Lubricating oil capacity : 300 cc (0.3 L) / 10,1 FL. OZ
- Lubricant : Airtek CE 555 synthetic lubricant
- Frame : Aluminium and powder coated steel
- Oil/Moisture separator : After last stage
- Filtration : Filter cartridge active carbon and molecular sieve
- Safety valve : On the separator housing
- Interstage coolers and after coolers : Stainless steel
- % Max O² : 40
- Membrane type : Nuvair Permea
- Breathing Air : DIN 3188 EN12021 CGA E
DNAx Nitrox membrane compressors. In other words a
compressor that "De-Nitrogenises Air" (DNA), or in layman's terms, takes air
throws away the nitrogen and saves what's left, "OXYGEN ENRICHED AIR".
The technology behind this system has been available for years but has only
been utilised in industry due to the size, complexity, and cost of the
membrane.
The new membranes now available do away with all these problems and provide
small, easily maintained, cost-effective units that can be used with most
compression systems or bought as a complete compression system in a purpose
built cabinet.
|
 |
|
Explorer 2 Nitrox
- Four Stage 4.2 SCFM High Pressure Compressor
- Fill O2% 21-40%
- 6cfm Membrane System
- Pro O2 Analyzer for Fill O2%
- Pick O2 Analyzer for Permeate Inline O2%
- 110 Volt Thermostatically Controlled Heater
- LP>LP Regulator for O2% Regulation
- LP Supply Pressure & Regulated Pressure Gauges
- Norgren Series 74 LP Filtration Auto Drains/DP Gauges, Coalescing 1.0
Micron, Polishing .01 Micron, Oil Vapor Removal .003 PPM
- 11hp Electric Start Honda, 13amp Charging Circuit
- Tach/Hour Meter
- 600 Watt Inverter
- 12 cfm Low Pressure Compressor
- 56 Litre Volume Tank
- 12 Volt Battery
- Options:
- Automatic Condensate Drains
- High Temperature Shut Down
- Automatic Fill Pressure Shut Down
- Preset Maximum fill blocks 3000psi & 4500 psi
This complete turn key Nitrox System is built for the
diver that wants to fill tanks while away from Dive Shops.
Nitrox and air fills while on remote vacations, home or offshore are easy
with this package.
|
 |
|
MCH 6/EM Explorer Nitrox - 2.8 cfm Single Phase Electric
- Charging rate : 80l/min - 6m3/h - 2.8 cfm
- Filling time cylinder : 10 L - 0-200 Bar 25 min
- Working pressure : 225 Bar 3200 psi
- Driven by : Single phase electric motor
- Power : 2,2 Kw - 3 HP
- Rpm : 2800 (230 V - 50 Hz) - 3400 (230 V - Hz / 115 V - 60 Hz)
- Full load Amps : 14 A (230 V - 50 Hz / 230 V - 60 Hz) - 29 A (115 V -
60 Hz)
- Measurements : H 55.8cm x L 129.5cm x W 40.6cm
- Weight : 63.5 KG
- Noise Level : 81.7 dB - ISO 3746
- Lubricating oil capacity : 300 cc (0.3 L) / 10,1 FL. OZ
- Lubricant : Airtek CE 555 synthetic lubricant
- Frame : Aluminium and powder coated steel
- Oil/Moisture separator : After last stage
- Filtration : Filter cartridge active carbon and molecular sieve
- % Max 0² : 40
- Safety valve : On the separator housing
- Interstage coolers and after coolers : Stainless steel
- Breathing Air : DIN 3188 EN12021 CGA E
- Membrane type : Nuvair Permea
DNAx Nitrox membrane compressors. In other words a
compressor that "De-Nitrogenises Air" (DNA), or in layman's terms, takes air
throws away the nitrogen and saves what's left, "OXYGEN ENRICHED AIR".
The technology behind this system has been available for years but has only
been utilised in industry due to the size, complexity, and cost of the
membrane.
The new membranes now available do away with all these problems and provide
small, easily maintained, cost-effective units that can be used with most
compression systems or bought as a complete compression system in a purpose
built cabinet.
|
 |
|
MCH 14/ET Standard Nitrox - 7 cfm Three Phase Electric
- Charging rate - 200l/min - 14m3/h - 7 cfm
- Driven by - Three phase electric motor
- Working pressure - 225 bar 3200 psi
- Noise Level - 80.7 dB - ISO 3746
- Weight - 130 KG
- Measurements - H 72cm x L 130cm x W 51cm
-
- 24 - 40 % :O²
DNAx Nitrox membrane compressors. In other words a
compressor that "De-Nitrogenises Air" (DNA), or in layman's terms, takes air
throws away the nitrogen and saves what's left, "OXYGEN ENRICHED AIR".
The technology behind this system has been available for years but has only
been utilised in industry due to the size, complexity, and cost of the
membrane.
The new membranes now available do away with all these problems and provide
small, easily maintained, cost-effective units that can be used with most
compression systems or bought as a complete compression system in a purpose
built cabinet.
|
 |
|
MCH 14 Tech Nitrox - 8.5 cfm Three phase Electric
- Charging rate - 240L/min - 14m3/h - 8.5 cfm
- Driven by - Three phase electric motors 2 x 5.5 Kw
- Working pressure - 225 bar 3200 psi
- Noise Level - 75 dB - ISO 3746
- Weight - 335 KG
- Measurements - H 133cm x L 89cm x W 85cm
-
- 24% - 40% O²
|
 |
|
Nitrox LP 280 Rotary Silent Compressor
The Nitrox LP 280 Rotary Silent production system consists
of a rotary screw low pressure compressor that supplies air to a membrane
system where oxygen rich air is separated away from nitrogen air. The oxygen
rich air (nitrox) is then mixed and delivered to the intake of a high
pressure compressor to be pumped into the tanks. The oxygen percentage is
available from 22.40 % by adjusting the regulated air input pressure. The
system utilizes a 7.5 Kw, 740l/m, 175 psi (12 bar) rotary screw compressor
mounted with a three-phase electric motor in a silenced cabinet.
Compressor system components include: low pressure rotary screw compressor,
volume tank with over pressure relief, condensate drain, motor and frame.
The nitrox system parts include: low pressure filtration to 0.003 ppm oil
vapour, low pressure regulator, heater with automatic thermostat control,
permeable membrane, mixing tube, compressor intake porting, permeate hose
for connection to your exsiting HP compressor intake, inline oxygen sensor
with analyzer to supply a reading of what oxygen % is going to your
compressor and a fill oxygen % analyzer with high pressure to low pressure
regulator to supply accurate readings of oxygen % from your compressor to
the tanks being filled. |
 |
|
Nitrox LP 560 Rotary Silent Compressor
- Simplest, Most Cost Effective Nitrox Systems Available
- Pump LP Nitrox containing 24-40% Oxygen
- None of the Costs, Hassles, or Hazards of O2 Blending
- Systems to Fit Most HP Compressors
- Vertical cabinet Minimizes Space Requirements
- Rotary Screw Lp Compressor Provides Quietest Operation & Lowest
Maintenance
- Nitrox Membrane System with (2) O2 Analyzers
- Microprocessor Controller Manages Pressures, Temperature, Run Time,
Maintenance, & Diagnostics
- Automatic Shutdowns for High Pressure & Temperature
- Automatic Condensate Drain
- Use with 6-45 cfm HP Breathing Air Compressors
- Includes Grade D LP Filtration for Membrane
|
 |
|
Nitrox LP 713 Rotary Silent Compressor
- One of the Simplest, Most Cost Effective Nitrox Systems Available
- Pump LP Nitrox containing 24-40% Oxygen
- None of the Costs, Hassles, or Hazards of O2 Blending
- Systems to Fit Most HP Compressors
- Vertical cabinet Minimizes Space Requirements
- Rotary Screw Lp Compressor Provides Quietest Operation & Lowest
Maintenance
- Nitrox Membrane System with (2) O2 Analyzers
- Microprocessor Controller Manages Pressures, Temperature, Run Time,
Maintenance, & Diagnostics
- Automatic Shutdowns for High Pressure & Temperature
- Automatic Condensate Drain
- Use with 6-45 cfm HP Breathing Air Compressors
- Includes Grade D LP Filtration for Membrane
|
 |
| |
|
| |
|
| |
|
| |
|
|